- Model:
-
L Series-42524152
Details: Schlage L Series Mortise Lock w/ HSLR Ligature Resistant Trim
Schlage offers a comprehensive portfolio of door hardware that reduces the risk of injury or death due to ligature strangulation in all areas, but the HSLR (High Security Ligature-Resistant) trim is specifically recommended for high-risk applications. The patented crescent-style handle design has quickly become the standard for ligature resistance and accessibility. It is recognized by the widely-accepted New York State Office of Mental Health (NYS-OMH) Patient Safety Standard and achieves a "paperclip protection" designation on the mortise chassis. Optional key override adds an anti-barricade safety feature on four functions helping prevent self-harm situations by allowing the key to override a thumbturn being held in a locked position.
Features & Benefits
Security
- Provides the highest level of ligature-resistance in an ADA compliant solution to positively contribute to healing environments
- “Paperclip Protection” designation as determined by NYS-OMH testing enables use in low-, medium- and high-risk areas
- HSLR mortise chassis is tested and certified to ANSI/BHMA Grade 1 operational and security standards
- UL listed for 3-hour fire door; spring-loaded fusible link inside lock case provides fail secure mode in case of fire
- Deadbolt functions include anti-saw pin in bolt to prevent cut-through
- Supplied with Torx® security screws
- Lock monitoring options include request to exit (RX), latchbolt (LX), door postion (DPS), and deadbolt (DM) (availability varies by function)
- Patented Everest 29™ S123 keyway is provided standard which prohibits unauthorized key duplication
Aesthetics
- Available in 630 Satin Stainless Steel finish
- ADA compliant - ”no pinch, no grasp”
Built To Last
- Two piece anti-friction tongue in latch bolt reduces wear
- Breakaway spindle keeps door secured in the event of vandalism
- Every Schlage lock undergoes intensive testing to determine its ANSI grade level including: cycle, resistance, door impact, warped door and bolt strength tests
Specifications
Chassis
- Case: Cold Rolled Steel (CRS) with corrosion resistant zinc dichromate plating
- Case size: 4-7/16" x 6 1/16" x 1" (113 mm x 154 mm x 25 mm)
- Door thickness: 1-3/4" (44 mm) standard
- Specify handing with order
Trim
- Crescent style handle design in cast stainless steel
- Large plate escutcheon: 6” x 13.17” x .32" (152 mm x 335 mm x 8 mm); cast brass
- Handle projection from door is 2.27" (58 mm)
- Available 1/8" thick lock case lead lining option for use in X-ray or other rooms with radiation concern
Latches
- Backset: 2-3/4" (70 mm) only
- Armor: Standard - 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm); Optional - 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm)
- Deadbolt: 1" (25 mm) throw stainless steel
- Latch: 3⁄4" (19 mm) throw stainless steel with anti-friction tongue
- Strike: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) standard; strike lip length: 1-3⁄16" (30 mm); dust box included
Applications
- Any high-risk behavioral health setting
- Hospital room doors
- Detention center doors